Function
|
Factory setting
|
Alternatives
|
Description
|
Temperature zone
|
TWO
|
ONE /
TWO
|
One or two zone control can be selected. If one zone control is selected then the display will always show the same value for the left and right-hand sides. The temperature can be selected with the buttons for the right or left-hand side.
|
Left Indoor Temperature Increase
|
0.0°C
|
-3.0°C -
+3.0°C
|
Cabin temperature can be raised (or lowered) in relation to the set temperature. A higher value results in a higher cabin temperature in the zone in question.
|
Right Indoor Temperature Increase
|
0.0°C
|
-3.0°C -
+3.0°C
|
Cabin temperature can be raised (or lowered) in relation to the set temperature. A higher value results in a higher cabin temperature in the zone in question.
|
Fan Delay
|
0 seconds
|
0-30 seconds
|
When there is a risk of misting on the windscreen in connection with starting the engine then the control module can delay fan start until the evaporation temperature has decreased so much that any moisture forms. The fan delay will be active at outside temperatures of 0-15°C, 0-20°C during low solar intensity.
|
Solar sensor
|
100
|
0-255
|
The value specifies how much the solar sensor affects the calculation of the temperature at head height for each respective zone in the front seat. A higher value results in a greater effect.
|
ACC Will Start in Defrost Below This Temperature
|
6°C
|
0-30°C
|
Cold start. The value specifies the outside temperature below which the air distribution starts in defrost mode.
|
Fan Speed Response at New Temperature Setting
|
30
|
0-255
|
The value specifies how much the fan current is increased in the short term if the temperature setting is changed. A higher value results in a greater effect.
|
Automatic Recirculation Below This Speed
|
10 km/h
|
0-30 km/h
|
Extended user programming. The speed limit for the speed-dependent recirculation can be adjusted. The value specifies the speed below which recirculation is selected. Fresh air is selected 20 km/h above this speed.
|
ECON Below This Temperature
|
10°C
|
0-18°C
|
Extended user programming. The outside temperature limit for ECON can be adjusted. The value specifies the outside temperature below which ECON is selected. ECON is disengaged 3°C above this temperature.
|
Parking Heater Temperature Control
|
AUTO
|
AUTO /100% HEAT
|
Parking heater. 100% heat or automatic temperature control can be selected.
|
Parking Heater Fan Current
|
6 A
|
5-10 A
|
Parking heater. The fan current can be adjusted.
|
Parking Heater Defroster Duration
|
25 min
|
0-60 min
|
Parking heater. The time that the control module chooses for the air distribution mode defrost can be adjusted. When the time has elapsed defrost/floor is selected.
|
Latest Manual Selection At Ignition On
|
NO
|
Yes /
No
|
If YES is selected then the control module will always choose the latest manual setting at ignition on.
|
Temperature Defroster -> Defroster/Floor at Cold Start
|
0°C
|
-10°C -
+10°C
|
Cold start. The coolant temperature at which the air distribution changes from defrost to defrost/floor can be changed in relation to the normal value, which is 65°C. A higher value results in a later changeover to defroster/floor.
|