Test readings, control module connections
Test readings, control module connections |
Remember: |
• |
Note the test conditions. Use common sense when assessing the test result.
|
• |
First check that the control module is supplied with current and is grounded.
Then check all sensor inputs and signals from other systems. Finally, check the control module outputs. Remember that the test readings do not indicate whether the actuator is working. |
• |
If any reading is not OK, consult the wiring diagram to trace the leads, connectors or components which should be checked more thoroughly.
|
• |
The test readings indicated refer to calibrated FLUKE 88/97.
|
• |
The test values indicate the pulse ratio and pulse length of the signal respectively. A test instrument for measuring pulse ratio and pulse width respectively must be used.
|
ACC unit, control module connections |
> = greater than < = less than ~ = alternating current (LP: LOGIC PROBE P = select pulse; p = visible pulses).
pin nr | Cable colour | Component/function | In/Out | Test conditions | Between X and Y | Test reading | |
1
|
BK
|
Control module ground
|
In
|
Ignition ON
|
4-1
|
B+
|
|
2
|
RD/WH
|
Air recirculation motor power supply
|
Out
|
Activate fresh air
|
2-21
|
+12V for approx. 10s
|
|
Activate air recirculation
|
2-21
|
-12V for approx. 10s
|
|||||
3
|
|
Parking heater connection
|
In
|
Activate parking heater
|
3-1
|
B+
|
|
4
|
BU/RD
|
Power supply +15
|
In
|
Ignition ON or activated control module
|
4-1
|
B+
|
|
5
|
OG/WH
|
B+ voltage ON fan control module
|
Out
|
Ignition ON
|
5-1
|
B+
|
|
6
|
GN/YE
|
Stepping motor, mixed-air, LH
|
Out
|
Ignition ON activate motor
|
6-25
|
50 Hz/ 50 %
LP Hi-Lo |
|
7
|
YE/BN
|
Stepping motor, mixed-air, LH
|
Out
|
Ignition ON activate motor
|
7-26
|
50 Hz/ 50 %
LP Hi-Lo |
|
8
|
RD/WH
|
Stepping motor, air distribution flap
|
Out
|
Ignition ON activate motor
|
8-27
|
50 Hz/ 50% LP Hi-Lo
|
|
9
|
RD/BU
|
Stepping motor, air distribution flap
|
Out
|
Ignition ON activate motor
|
9-28
|
50 Hz/ 50% LP Hi-Lo
|
|
10
|
WH/BK
|
Stepping motor, mixed-air, RH
|
Out
|
Ignition ON activate motor
|
10-29
|
50 Hz/ 50% LP Hi-Lo
|
|
11
|
RD/BU
|
Stepping motor, mixed-air, RH
|
Out
|
Ignition ON activate motor
|
11-30
|
50 Hz/ 50% LP Hi-Lo
|
|
12-13
|
|
No connection
|
|
|
|
|
|
14
|
GN/BU
|
Fan control module control voltage
|
Out
|
Ignition ON change fan speed
|
14-1
|
0-5 V
|
|
15
|
|
No connection
|
|
|
|
|
|
16
|
YE/GN
|
Solar sensor, B+ power supply and clock pulse
|
Out
|
Ignition ON
|
16-36
|
12 V, 25 Hz, TRIGG, 1%, LP Hi-Lo p
|
|
17
|
WH
|
Solar sensor test lead
|
In
|
Ignition ON
|
17-36
|
0-5V PULSETRAIN LP Hi-Lo p
|
|
18
|
BN/RD
|
Mixed-air temperature sensor, RH
|
In
|
Ignition ON
|
18-37
|
see Technical data
|
|
19
|
BN/OG
|
Mixed-air temperature sensor, LH
|
In
|
Ignition ON
|
19-38
|
see Technical data
|
|
20
|
OG/WH
|
Cabin temperature sensor
|
In
|
Ignition ON
|
20-39
|
see Technical data
|
|
21
|
GN/WH
|
Air recirculation motor power supply
|
Out
|
Activate air recirculation
|
21-2
|
+12V for approx. 10s
|
|
Activate fresh air
|
21-2
|
-12V for approx. 10s
|
|||||
22
|
RD
|
Power supply +30
|
In
|
Power supply +30
|
22-1
|
B+
|
|
23
|
WH
|
Circulation pump
|
Out
|
Activate motor
|
4-23
|
B+
|
|
24
|
WT/GN
|
Heat exchanger shut-off valve
|
Out
|
Ignition ON
|
4-24
|
B+
|
|
25
|
VT/WH
|
Stepping motor, mixed-air, LH
|
Out
|
Ignition ON
Activate motor |
25-6
|
50 Hz/ 50 %
LP Hi-Lo |
|
26
|
YE/WH
|
Stepping motor, mixed-air, LH
|
Out
|
Ignition ON
Activate motor |
26-7
|
50 Hz/ 50% LP Hi-Lo
|
|
27
|
WH/YE
|
Stepping motor, air distribution flap
|
Out
|
Ignition ON
Activate motor |
27-8
|
50 Hz/ 50% LP Hi-Lo
|
|
28
|
RD/VT
|
Stepping motor, air distribution flap
|
Out
|
Ignition ON
Activate motor |
28-9
|
50 Hz/ 50% LP Hi-Lo
|
|
29
|
WH
|
Stepping motor, mixed-air, RH
|
Out
|
Ignition ON
Activate motor |
29-10
|
50 Hz/ 50% LP Hi-Lo
|
|
30
|
BK/VT
|
Stepping motor, mixed-air, RH
|
Out
|
Ignition ON
Activate motor |
30-11
|
50 Hz/ 50% LP Hi-Lo
|
|
31-32
|
|
No connection
|
|
|
|||
33
|
GN
|
I-Bus (+)
|
In/Out
|
Ignition ON
|
33-1
|
2-3 V
|
|
34
|
WH
|
I-Bus (-)
|
In/Out
|
Ignition ON
|
34-1
|
2-3 V
|
|
35
|
WH/GN
|
Fan control module reference ground
|
Out
|
Ignition ON
|
5-35
|
B+
|
|
36
|
BU/RD
|
Solar sensor, ground
|
Out
|
Ignition ON
|
16-36
|
12 V, 25 Hz, TRIGG, 1%, LP Hi-Lo p
|
|
37
|
VT
|
Mixed-air temperature sensor, right ground
|
Out
|
Ignition ON
|
18-37
|
see Technical data
|
|
38
|
BN/WH
|
Mixed-air temperature sensor, LH ground
|
Out
|
Ignition ON
|
19-38
|
see Technical data
|
|
39
|
YE/WH
|
Inside temperature sensor ground
|
Out
|
Ignition ON
|
20-39
|
see Technical data
|