B1800
Read the instructions below then start the fault diagnostic procedure.
Symptom: Memory setting does not work.
B1800 |
Common Output to All Motors. Short to B+
Common Output to All Motors. Open Circuit / Short to Ground
Fault symptoms
Memory setting does not work.Condition
Open circuit/shorting to ground. Short-circuit to B+.Check the wiring
Jiggle the wiring harness at several points and in different directions to detect intermittent breaks and short-circuits in the leads. Observe the multimeter, test lamp or diagnostic tool during the test.Diagnostic help
The control module outputs can be activated with the diagnostic tool. See tableImportant | ||
This diagnostic trouble code may be generated if the mirrors are adjusted manually at the same time as the memory setting or tilt function is activated. |
||