Stepping motor, air-mixing RH
|
Stepping motor, air-mixing RH
|
Put the air-mixing control to max cold or max heat before commencing removal.
1.
|
Remove the glove compartment, se group 8, Interior equipment
, ā€¯Adjustment and replacementā€¯.
Remove the trim from the side of the centre console.
|
2.
|
Remove the stepping motor, 2 bolts.
|
When fitting, the lower flap must be positioned at the same end position as the upper flap.
Fit in reverse order.
Note
|
When fitting the stepping motor, grasp the air-blending flap via the floor air duct, otherwise the flap may jump out of its mounting.
|