1.
|
Basic calculation of fuel quantity/combustion
The current air mass/combustion is divided by 14.7 and sent to box 2. The unit is now mg fuel/combustion.
|
2.
|
Compensation
In the case of a cold engine, shortly after starting, rapid load changes, knocking or high loads, the current value is multiplied by a compensation factor.
|
3.
|
Closed loop
The closed loop value is used as a multiplier. The value is sent to box 4.
|
4.
|
Correction for purging
Multiply by the value for purge adaptation. The value is sent to box 5.
|
5.
|
Multiplicative adaptation
The multiplicative adaptation value is used as a multiplier and the new value is sent to box 6.
|
6.
|
Additive adaptation
The additive adaptation value is added and the new value sent to box 7.
|
7.
|
Starting fuel quantity
If the engine has not yet started, starting fuel is selected. The value is sent to box 8.
|
8.
|
Fuel quantity/combustion to be injected
The fuel quantity/combustion is the amount of petrol to be supplied to the engine. The value is sent to box 9.
|
9.
|
Injector opening duration
Converts the value to the time during which the injector must be open and the new value is sent to box 10.
|
10.
|
Injection twice/combustion
Injection takes place twice/combustion until the camshaft position has been found. Injection duration is divided by two. The value is sent to box 11.
|
11.
|
Voltage dependent needle lift duration added
Adds the injector time delay, which is voltage dependent. The value is sent to box 12.
|
12.
|
Fuel shut-off
The value is sent to box 13 unless fuel shut-off is active.
|
13.
|
Activation of injector
At a determined crankshaft angle, the microprocessor will control the transistor for the injector that is next in the firing order.
|