SAAB WIS ONLINE

Fuel shut-off

Fuel shut-off


Fuel shut-off will take place if any of the following criteria are fulfilled:


+15 supply missing

fully depressed accelerator pedal during starter motor cranking

engine speed above (depending on coolant temperature.):

- engine coolant temperature <60° - above 6300 rpm

- engine coolant temperature >80° - above 6400 rpm

air mass/combustion above:

- B235E: above 1100 mg/c

- B235R: above 1350 mg/c

immobilizer code incorrect

throttle rotated manually while engine running

major fault in throttle control

in case of a pedal sensor malfunction if the engine speed exceeds 2200 rpm

ignition discharge module not powered

engine speeds above 1800 rpm with accelerator pedal fully released and coolant temperature exceeding 20°C. For manual gearbox this applies to 3rd, 4th, and 5th gears. For cars with automatic transmission this applies to 2nd, 3rd, and 4th gears. Fuel injection is reactivated at 1400 rpm.


Diagnostics

If TWICE fails to send ”Immobilizer OFF” when the ignition is turned on or if the Trionic T7, TWICE or MIU control modules have been replaced and the immobilizer code has not been programmed in TWICE, diagnostic trouble code P1460 will be generated and the engine will not start.