SAAB WIS ONLINE

EVAP canister purge valve

EVAP canister purge valve

To remove



1. Release the snap-on coupling on the purge hose to the evap canister with tool no. 83 95 261. Press down the brace.

2. Remove the evap canister purge valve from the bracket.

3. Carefully twist the evap canister purge valve and unplug the connector.

4. Loosen the evap canister purge valve from the connecting hose.


To fit


Note

Spray the connector with Kontakt 61 contact cleaner (part no. 30 04 520).



1. Connect the evap canister purge valve to the connecting hose.

2. Plug in the evap canister purge valve connector.

3. Fit the evap canister purge valve to the bracket.

4. Fit the snap-on coupling on the purge hose to the evap canister.