EVAP canister purge valve
|
EVAP canister purge valve
|
1.
|
Release the snap-on coupling on the purge hose to the evap canister with tool no. 83 95 261. Press down the brace.
|
2.
|
Remove the evap canister purge valve from the bracket.
|
3.
|
Carefully twist the evap canister purge valve and unplug the connector.
|
4.
|
Loosen the evap canister purge valve from the connecting hose.
|
Note
|
Spray the connector with Kontakt 61 contact cleaner (part no. 30 04 520).
|
1.
|
Connect the evap canister purge valve to the connecting hose.
|
2.
|
Plug in the evap canister purge valve connector.
|
3.
|
Fit the evap canister purge valve to the bracket.
|
4.
|
Fit the snap-on coupling on the purge hose to the evap canister.
|