P0137
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Market US/CA: CHECK ENGINE
O2S Circuit. Low Voltage. Sensor 2.
Fault symptoms
•
|
Market US/CA: CHECK ENGINE
|
On-Board Diagnostics
Type of diagnosis:
-
|
Continuous. But interrupted when fault criteria fulfilled and will not restart until next driving cycle.
|
Enable criteria:
-
|
General conditions for this trouble code: Atmospheric pressure must exceed 72 kPa and the engine coolant and intake air temperature must exceed -7°C.
|
-
|
Engine running. Main relay voltage exceeding 10V.
|
Fault criteria:
-
|
Voltage below 0.25 V for more than 2 s.
|
Dependents:
System reaction to a fault:
-
|
Transition adaptation of closed loop is blocked.
|
OK report:
-
|
P0140 diagnosis performed once and fault criteria not fulfilled. Fault criteria for P0138 not fulfilled.
|
Fault handling:
(See “Fault diagnosis, general” for more information.)
Diagnostic help
Fault diagnosis concerns electrical faults in connected leads or in the sensor.
Diagnostic tool functions related to this fault are:
•
|
Diagnostic status for the diagnosis.
|
•
|
Heated oxygen sensor reading, in V.
|
For more information, see “Fault diagnosis, general".
Note
|
Oxygen sensor receives reference oxygen from the surrounding air via the connecting cables. For this reason, electrical contact spray or grease
must not
be used on the oxygen sensor connector.
|
Check the wiring
Jiggle the leads and in-line connectors at various points and in different directions to detect any intermittent breaks or short circuits in the wiring. Observe the multimeter, test lamp or diagnostic tool while doing this.