SAAB WIS ONLINE

P1452

Read the instructions below then start the fault diagnostic procedure.

Symptom: CHECK ENGINE.

P1452


EVAP Tank Pressure Sensor. Value too low when Depressurized.



Fault symptoms


CHECK ENGINE.


On-Board Diagnostics

Type of diagnosis:


- Once per driving cycle. Interrupted when fault criteria fulfilled or OK reported. Restarts next driving cycle.


Enable criteria:


- General conditions for this trouble code: When starting the engine, the atmospheric pressure must exceed 78 kPa and the engine coolant and intake air temperatures must exceed -7°C.

- Approved transition diagnosis of oxygen sensor 1. Purge active. Idling. Max. one change in status of brake light switch. Purge adaptation higher than -7 %. Car stationary for 8 sec.

The diagnosis will start once the above conditions have been fulfilled. If the diagnosis is interrupted then the speed must exceed 0 on one occasion before it is allowed to restart.


Fault criteria:


- Tank pressure below 1.8 kPa for 6.5 s.


Dependents:


- P0444, P0445, P0501, P0502, P0506, P0507, P1444, P1445, P1576 and P1577.


System reaction to a fault:


- Integrity diagnosis of purge system blocked. Purge and fuel adaptation blocked.


OK report:


- Diagnoses for P1451, P1452 and P1453 performed once and fault criteria not fulfilled. Fault criteria for P0452 or P0453 not fulfilled.


Fault handling: (See section Fault handling III, other emission-related components and functions for more information.)


- Type III.


Diagnostic help

Fault diagnosis concerns checking tank pressure equalization to atmosphere or electrical fault in connecting leads or in the sensor.

Functions in the diagnostic tool related to the fault:


Diagnostic status for the diagnosis.

Pressure sensor value, unit kPa. The value should be about 0 kPa when the filler cap is removed.


See also description of readings under "Read Values" menu for more information.

Checking the wiring

Jiggle the wiring harness at several points and in different directions to detect intermittent breaks and short circuits. Observe the multimeter, diagnostic tool or test lamp during the check.