Checking the charge air bypass valve, V6
| Checking the charge air bypass valve, V6 | 
| 1. | 
        Disconnect the vacuum hose from the charge air bypass valve.
         
        
         | 
      |
| 2. | 
        Connect the pressure/vacuum pump,
        
         30 14 883 Pressure/vacuum pump
        
        , and build negative pressure in the valve.
         | 
      |
| 3. | 
        Check that the diaphragm is intact. If the diaphragm is damaged, no vacuum can be created.
         | 
      |
| 4. | 
        Repeat points 2 and 3 but pump up a pressure.
         
        
         | 
      |
| 5. | 
        Disconnect the pump.
         | 
      |
| 6. | 
        Connect the vacuum hose.
         | 
      |