SAAB WIS ONLINE

P0758

Read the instructions below then start the fault diagnostic procedure.

Symptom: CHECK GEARBOX warning lamp is on. TCM in Limp-Home mode.

P0758


Solenoid 2-3. Short to Ground.

Solenoid 2-3. Open Circuit / Short to B+.


Fault symptoms

CHECK GEARBOX warning lamp is on.

TCM in Limp-Home mode.

Conditions

Shorting to ground

Shorting to B+/Open circuit.

Diagnostic help

The status of the 2-3 shift solenoid (S2) can be ascertained with the diagnostics instrument.

The 2-3 shift solenoid (S2) should be activated (ON) in 1st and 2nd gears when the car is being driven and not activated (OFF) in the other gears.

The 2-3 shift solenoid (S2) can be activated with the diagnostics instrument.


- Select " Data Display / Output Control (New)" and " Solenoid 2-3"