SAAB WIS ONLINE

"Activate" menu

"Activate" menu

Note

When a system function is activated with the diagnostics tool, the control module executes a command which is not normal from a functional point of view. In activation mode the diagnostics tool checks the control module and the activation command should therefore be used with discrimination. An activated function will always be reset when you leave the activation mode and continue in the diagnostics tool's menu.

Always clear any diagnostic trouble codes that may have been generated in the transmission system or any other system when you have finished your work.


Important

Activation mode can only be entered in selector lever position N. In other selector lever positions the diagnostics tool's display will show SHIFT TO N AND THEN PRESS ENTER. All activation commands can be cancelled by pressing Exit.


Activate

Condition Activation

Description

Usage

Solenoid 1-2/3-4

Ignition ON

The control module activates the 1-2/3-4 shift solenoid (S1).

If in working order the solenoid will click.

Solenoid 2-3

Ignition ON

The control module activates the 2-3 shift solenoid (S2).

If in working order the solenoid will click.

Solenoid Lock Up

Ignition ON

The control module activates the Lock-up solenoid (SL).

If in working order the solenoid will click. A stethoscope should be used.

Solenoid Pressure Regulation

Ignition ON

The control module activates the pressure control solenoid (ST). The solenoid is activated with 250 mA and 910 mA alternately. The current values are approximate and are presented on the diagnostics tool's display.

If in working order the solenoid will click. A stethoscope should be used.