SAAB WIS ONLINE

Test readings, control module connections

Test readings, control module connections

Extent


The following pages contain values and instructions for obtaining readings of signals and levels on the control module.

Remember


Note the test conditions and use your common sense when judging the test results.

First check that the control module is supplied with current and grounded.

Then check all sensor inputs and signals from other systems.

Check the control module outputs last. Remember that the test readings do not indicate whether or not the actuator is working.

If any reading is not OK, consult the wiring diagram to trace the leads, connectors or components which ought to be checked more thoroughly.


The test readings given apply to a correctly calibrated Fluke 88/97.

The readings indicate the pulse ratio and pulse duration of the signal. A test instrument capable of measuring both pulse ratio and pulse duration must be used. The + sign denotes a positive trigger pulse (TRIG+).





Pin Component/Function In/Out Test conditions Between X and Y Measurement value (V)
1

Power supply +30

In



1-8

B+

2

Power supply (+15 circuit)

In

Ignition ON

2-8

B+

3

Switch, downward angling

In

Ignition ON

Button in neutral

Button pressed in

3-8



B+

< 0,5

4

Power supply, potentiometers, left door

Out

Ignition ON

4-8

4-6

5

Power supply, potentiometers, right door

Out

Ignition ON

5-8

4-6

6

Ground, potentiometers, left door

In

Ignition ON

6-fuse grounding point

< 0,5

7

Ground, potentiometers, right door

In

Ignition ON

7-fuse grounding point

< 0,5

8

Ground

In



8-fuse grounding point

< 0,5

9

Potentiometer, horizontel, left door

Out

Ignition ON

9-7

0,5-4,5

10

Potentiometer, horizontel, right door

In

Ignition ON

10-7

0,5-4,5

11

Potentiometer, vertical, right door

In

Ignition ON

11-7

0,5-4,5

12

Potentiometer, vertical, left door

In

Ignition ON

12-7

0,5-4,5

13

Motor, vertical, right door

Out

Ignition ON

See table

13-7

B+

< 0,5

14

Motor, horizontal, right door

Out

Ignition ON

See table

14-7

B+

< 0,5

15

Motor, horizontel, left door

Out

Ignition ON

See table

15-7

B+

< 0,5

16

Motor, vertical, left door

Out

Ignition ON

See table

16-7

B+

< 0,5

17

Motor, common output

Out

Ignition ON

See table

17-7

B+

< 0,5

18

No connection









19

I-Bus (+)

In/Out

Ignition ON

19-8

2-3

20

I-Bus (-)

In/Out

Ignition ON

20-8