P0118
Read the instructions below then
start the fault diagnostic procedure.
Symptom: CHECK ENGINE.
A/C malfunctioning.
Radiator fan running continuously when ignition is ON.
Temperature gauge displaying incorrect value.
Misfiring can occur before trouble code is generated.
Engine Coolant Temperature Sensor Circuit. Short to B+ / Open circuit.
Fault symptoms
•
|
Radiator fan running continuously when ignition is ON.
|
•
|
Temperature gauge displaying incorrect value.
|
•
|
Misfiring can occur before trouble code is generated.
|
On-Board Diagnostics
Type of diagnosis:
-
|
Continuous. But interrupted when fault criteria fulfilled and will not restart until next driving cycle.
|
Enable criteria:
Fault criteria:
-
|
Voltage higher than 4.910 V for more than 1 s.
|
Dependents:
System reaction to a fault:
-
|
A substitute value is calculated continuously as follows: Starting intake air temperature is incremented with 1°C per 60 g air mass/s. The value is maximized to 90°C and is used as soon as fault criteria for the sensor are fulfilled.
|
OK report:
-
|
P0116 Test 1 and Test 2 performed once and fault criteria not fulfilled. Fault criteria for P0117 or P0118 not fulfilled.
|
Fault handling:
(See section
Fault handling III, other emission-related components and functions
for more information.)
Diagnostic help
Fault diagnosis concerns an electrical fault in connecting leads or in the sensor.
Functions in the diagnostic tool related to the fault:
•
|
Diagnostic status for the diagnosis.
|
•
|
Temperature sensor reading, in °C.
|
See also description of readings under
"Read Values" menu
for more information.
Checking the wiring
Jiggle the wiring harness at several points and in different directions to detect intermittent breaks and short circuits. Observe the multimeter, diagnostic tool or test lamp during the check.
See
P0117
.