P0116

Read the instructions below then start the fault diagnostic procedure.

Symptom: CHECK ENGINE. A/C not working. Radiator fan runs continuously when ignition is ON. Temperature gauge reading incorrect. Possible misfiring before DTC is generated.

P0116


Engine Coolant Temperature Circuit. Performance Problem.





Fault symptoms


CHECK ENGINE.

A/C not working.

Radiator fan runs continuously when ignition is ON.

Temperature gauge reading incorrect.

Possible misfiring before DTC is generated.


On-Board Diagnostics

Type of diagnosis:


- Once per driving cycle. Interrupted when fault criteria fulfilled or OK reported. Restarts next driving cycle.


Enable criteria:


- General conditions for this trouble code: Atmospheric pressure must exceed 72 kPa and the engine coolant and intake air temperature must exceed -7°C.

- Test 1: Engine running. A counter accumulates the time during which the mass air flow has exceeded 10 g/s. Counter has reached 400 s.

- Test 2: Engine running. A substitute value is calculated for the engine coolant temperature: The starting intake air temperature is incremented with 1°C per 60 g air mass/s. A counter accumulates the time during which the air mass flow has exceeded 10 mg/s. An maximum is set for the substitute value after 350 s that is dependent on the intake air temperature (normally 65-80°C). The maximum value is set as soon as the air mass/combustion is not too high and the air mass/s is not too low, so that the intake air temperature will be as close as possible to the outdoor temperature. After 400 s, the sensor value will be compared with the substitute value.


Fault criteria:


- Test 1: Sensor value has changed less than 1°C.

- Test 2: Sensor value more than 20°C below substitute value or more than 48°C above substitute value.


Dependents:


- P0112 and P0113.


System reaction to a fault:


- A substitute value is calculated continuously as follows: Starting intake air temperature is incremented with 1°C per 60 g air mass/s. The value is maximized to 90°C and is used as soon as fault criteria for the sensor are fulfilled.


OK report:


- Test 1 and Test 2 performed once and fault criteria not fulfilled. Fault criteria for P0117 or P0118 not fulfilled.


Fault handling: (See “Fault diagnosis, general” for more information.)


- Type III.


Diagnostic help

Fault diagnosis concerns electrical faults in connected leads or in the sensor.

Diagnostic tool functions related to this fault are:


Diagnostic status for the diagnosis.

Temperature sensor reading, unit °C.


See also the description of test values under ”Fault diagnosis, general” for more information.

Check the wiring

Jiggle the leads and in-line connectors at various points and in different directions to detect any intermittent breaks or short circuits in the wiring. Observe the multimeter, test lamp or diagnostic tool while doing this.