P0134
Read the instructions below then start the fault diagnostic procedure.
Symptom: CHECK ENGINE. Misfiring can occur before trouble code is generated.
P0134 |
Fault symptoms
• |
CHECK ENGINE.
|
• |
Misfiring can occur before trouble code is generated.
|
On-Board Diagnostics
Type of diagnosis:- |
Continuous. But interrupted when fault criteria fulfilled and will not restart until next driving cycle.
|
Enable criteria:
Test 1: Engine running. Main relay voltage above 10V. Preheating active for longer than 8 min.
Test 2: Closed loop active.
Fault criteria:
- |
Test 1: Voltage has not been outside the range 0.300- 0.600 V.
|
- |
Test 2: Closed loop active and voltage has not been outside the range 0.300-0.600 V for 10 s.
|
Dependents:
- |
P1135 and P1136
|
System reaction to a fault :
- |
Closed loop is blocked.
|
OK report:
- |
Test 1 and Test 2 performed once and fault criteria not fulfilled. 60 s. has past and closed loop is still active. Fault criteria for P0131 or P0132 not fulfilled.
|
Fault handling: (See section Fault handling III, other emission-related components and functions for more information.)
- |
Type III.
|
Diagnostic help
Fault diagnosis concerns an electrical fault in connecting leads or in the sensor.Functions in the diagnostic tool related to the fault:
• |
Diagnostic status for the diagnosis.
|
• |
Oxygen Sensor Value, unit V.
|
See also Menu "Read Values" for more information.
Note | ||
Oxygen sensor receives reference oxygen from the surrounding air via the connecting cables. For this reason, electrical contact spray or grease must not be used on the oxygen sensor connector. |