P1131
Read the instructions below then
start the fault diagnostic procedure.
Symptom: CHECK ENGINE.
O2S. Switch point - lean. Sensor 1
Fault symptoms
On-Board Diagnostics
Type of diagnosis:
-
|
Continuous. Terminated when fault criteria fulfilled. Restarts next driving cycle.
|
Enable criteria:
-
|
General conditions for this trouble code: Atmospheric pressure must exceed 72 kPa and the engine coolant and intake air temperature must be above -70°C.
|
-
|
Engine running. Closed loop blocked in rich or lean mode for a number of combustions in order to maintain a voltage of 0.6V from oxygen sensor 2. The number of combustions that is required is adapted.
|
Fault criteria:
-
|
Closed loop blocked in rich mode for more than 35 combustions.
|
Dependents:
-
|
P0115, P0116, P0117, P0118, P0119, P0131, P0132 and P0134.
|
System reaction to a fault:
OK report:
-
|
Number of adapted combustions has dropped at some time during the driving cycle.
|
Fault handling:
(See section
Fault handling III, other emission-related components and functions
for more information.)
Diagnostic help
Fault diagnosis concerns an internal fault in the sensor.
Functions in the diagnostic tool related to the fault:
•
|
Diagnostic status for the diagnosis.
|
See also description of
Menu "Read Values"
for more information.
Note
|
Oxygen sensor receives reference oxygen from the surrounding air via the connecting cables. For this reason, electrical contact spray or grease
must not
be used on the oxygen sensor connector.
|