Before changing the turbo unit

Before changing the turbo unit

Change oil and filter




1. Raise the car, place a receptacle under the car and drain the oil via the drain plug in the oil sump. Refit the drain plug.

2. Lower the car and fill with oil to the MAX mark. The distance between the marks corresponds to a volume of 1 litre (1.05 qts).

3. Start the engine and let it idle until the thermostat opens (radiator fan starts).

4. Raise the car and drain the oil. Refit the drain plug.

Tightening torque: 25 Nm (19 lbf ft)

5. Undo the oil filter using the filter wrench and remove the filter. Wipe clean the surface sealing on the engine.



6. Oil the rubber gasket on the new oil filter and fit it. Tighten the filter by hand.

7. Lower the car and fill with oil to the MAX mark. The distance between the marks corresponds to a volume of 1 litre (1.05 qts).

8. Make sure there are no oil leaks after starting the engine.


Oil capacity

4.0 litres (4.3 qts) including filter

Oil type

See Lubricants