SAAB WIS ONLINE

Checking the charge air bypass valve, 4-cyl.

Checking the charge air bypass valve, 4-cyl.



1. Disconnect the vacuum hose from the charge air bypass valve.


2. Connect the pressure/vacuum pump, 30 14 883 Pressure/vacuum pump , and build negative pressure in the valve.

3. Check that the diaphragm is intact. If the diaphragm is damaged, no vacuum can be created.

4. Repeat points 2 and 3 but pump up a pressure.


5. Disconnect the pump.

6. Connect the vacuum hose.