SAAB WIS ONLINE

Power supply

Power supply

Battery voltage (+30 circuit)



Current (+30 circuit) is supplied to pin 7 (K12) of the main instrument unit via fuse 17.

The control module uses current from the +30 circuit for its memory.

Battery voltage (+15 circuit)

Current (+15 circuit) is supplied to pin 1 (K12) and pin 6 (K12) of the main instrument unit via fuse 27.

The main instrument unit is activated by current from the +15 circuit.

Diagnostics

If +30 is missing, the tripmeter will reset each time the ignition is turned off.

If no +15 current is present, the main instrument unit will not be "woken up". The engine will not start as bus communication has not been "awakened".

The function has no diagnostics.