SAAB WIS ONLINE

Menu "Read Values"

Menu "Read Values"

Text

Unit

Min.

Max.

Description

Outdoor Temperature

°C/°F

-40

50

Read the unfiltered value for the outdoor temperature.



Outdoor Temperature, Filtered

°C/°F

-40

50

The SID unit's internal filtered value for outdoor temperature. Filtering takes place as follows:


+1°C change every 6 minutes at speeds below 30 km/h.

+1°C change every 30 seconds at speeds above 30 km/h.

-1°C change every 2.5 seconds.


Rheostat Sensor

Volt

0

5.00

Voltage across the resistor in the rheostat. The voltage changes linearly from 0 V (max. rheostat level) to approx. 3.5 V (min. rheostat level).



Rheostat, Filtered

%

0

100

Rheostat value, converted internally into %


When the main lights switch is OFF and fuse 35 removed, the rheostat level is 0%.

When the interior lighting exceeds a certain level, the rheostat level is 0%.

When the main lights switch is ON, the rheostat level can be adjusted between 25 and 99%.


Rheostat Night Panel, Filtered

%

0

100

Rheostat value, converted internally into %, reduced by a fixed value.



LCD Dimmer Value, Filtered

%

0

100

Lighting value for display converted internally into %. The value is calculated from the rheostat level and the level of the light intensity in the car.



Indoor Light Sensor

%

0

100

Value from light sensor for interior light intensity in %.



Indoor Light Intensity, Filtered

lux

0

2000

The SID unit's internal filtered value for interior light intensity.



Steering Wheel Control

Volt

0

5.00

The steering wheel button set consists of 7 series-linked resistors which are powered with +5V from SID.

When a button is pressed, the resistor concerned is grounded, giving the relevant voltage. See for voltage values.

For cars without steering wheel controls, the voltage value applies only to the horn switch.



Steering Wheel Buttons

NONE

NXT

DOWN

UP

SRC

VOL PLUS

VOL MINUS



0

8

Internal conversion from voltage to show which button has been pressed. See ,

Coolant Fluid Level Sw

Inactive/

ACTIVE

0

1

The sensor opens the circuit to ground when the coolant level is low.



Washer Fluid Level Sw

Inactive /

ACTIVE

0

1

The sensor opens the circuit to ground when the washer fluid level is low.



Front Lamp Failure

NO /

YES

0

1

SID powers the filament monitor which grounds this input on a fault in any of the front bulbs.



SID Buttons

NONE /

C- /

C+ /

NIGHT PANEL /

TRIP UP /

TRIP DOWN /

SET /

CLEAR



0

128

The button set on SID can be read using this command. See

Horn Button

Off

On

0

1

The horn button value from the steering wheel, converted from voltage to show whether the button was pressed ON/OFF. See for reading voltages from sensors.



Parking Heater

Off

On

0

1

If the parking heater is connected as an accessory, the input from the timer can be read. For this type of connection, SID must be programmed to be able to control the function.



Month



1

12

SID has a stored real-time clock which keeps a record of the day, month, hour, minute and second.

To set the clock, see .



Day



1

31

SID has a stored real-time clock which keeps a record of the day, month, hour, minute and second.

To set the clock, see .



Hour



0

24

SID has a stored real-time clock which keeps a record of the day, month, hour, minute and second.

To set the clock, see .



Minutes



0

60

SID has a stored real-time clock which keeps a record of the day, month, hour, minute and second.

To set the clock, see .



Seconds



0

60

SID has a stored real-time clock which keeps a record of the day, month, hour, minute and second.

To set the clock, see .



Key not accepted

Inactive/

ACTIVE

0

1

The request to show the message comes from TWICE via the bus. The message can be disabled.



Days Until Service

Days

0

365

Shows the number of days remaining until service.