Control module power supply
Control module power supply |
Battery voltage (+30 circuit) |
Current (+30 circuit) is supplied via fuse 8 (22a) to pin 5 of the SID connector.
Battery voltage (+15 circuit) |
Current (+15 circuit) is supplied via fuse 27 (22a) to pin 25 of the SID connector.
The SID is activated by current from the +15 circuit.
Diagnostics |
If no current from the +30 circuit is present, the display will not be active and diagnostic communication will not be possible.
If no current from the +15 circuit is present, the display will not be active but can be turned on via the bus by switching on the radio, for example. Diagnostic communication will be possible with limited functions if the ignition key is turned to ON.
The SID will not generate a diagnostic trouble code if no current is present from either the +30 or +15 circuits.