B2355
Read the instructions below then start the fault diagnostic procedure.
Symptom: Temperature sensor in evaporator stops functioning, which means that the A/C system does not supply cold air.
B2355 |
Evaporator Temperature Sensor. Short to Ground
Evaporator Temperature Sensor. Open Circuit / Short to B+
Evaporator Temperature Sensor. Out of Range
Fault symptoms
Temperature sensor in evaporator stops functioning, which means that the A/C system does not supply cold air.Diagnostic help
The evaporator temperature can be read on the diagnostic tool.A reference resistor is useful when diagnosing a faulty sensor. This would give the following readings on the diagnostic tool:
• |
6.2 kohm gives approx. 20°C.
|
• |
and 11 kohm gives approx. 8°C.
|