SAAB WIS ONLINE

B2360

Read the instructions below then start the fault diagnostic procedure.

Symptom: No cold from the A/C system.

B2360


A/C Pressure Sensor. Short to Ground

A/C Pressure Sensor. Open Circuit / Short to B+


Fault symptoms

No cold from the A/C system.

Conditions

Short to ground is set if:


the control module's pin 9 is short circuited to ground.

the voltage is below normal measuring range.


Open Circuit/Short to B+ is set if:


the control module's pin 9 is short circuited to B+.

the voltage is above normal measuring range.


Diagnostic help

The pressure in the A/C system can be read using the diagnostic tool.

In the event of an open circuit in the wiring DICE switches off power supply (pin 38) 0.5s after ignition.