Temperature/pressure limits
| Temperature/pressure limits | 
| Thermostat, opening temperature | °C(°F) | 89 ± 2 (192 ± 4) | |
| System boiling point | °C(°F) bar | 131 (268) 1.4 | |
| The temperature gauge goes into the red zone at | °C(°F) | 129 ± 2.5 (264 ± 5) | |
| Expansion tank pressure valve, opening pressure | kPa | 140 - 150 | |
| 4-cyl. | |||
| Radiator fan, coolant temperature | turn-on, low speed turn-on, high speed | °C(°F) | 100 ± 2 (212 ± 4) 113 ± 2 (235 ± 4) | 
|  | turn-off, low speed turn-off, high speed | °C(°F) | 96 ± 1 (205 ± 2) 109 ± 1 (228 ± 2) | 
| V6 | |||
| Radiator fan, coolant temperature | turn-on, low speed turn-on, high speed | °C(°F) | 97 ± 2 (207 ± 4) 107 ± 2 (225 ± 4) | 
| turn-off, low speed turn-off, high speed | °C(°F) | 93 ± 1 (199 ± 2) 103 ± 1 (217 ± 2) | |

 
		