SAAB WIS ONLINE

P1445

Read the instructions below then start the fault diagnostic procedure.

Symptom: CHECK ENGINE.

P1445


Canister Close Valve Circuit. Short to B+.


Fault symptoms


CHECK ENGINE.


On-Board Diagnostics

Type of diagnosis:


- Continuous. But interrupted when fault criteria fulfilled and will not restart until next driving cycle.


Enable criteria:


- General conditions for this trouble code: Atmospheric pressure must exceed 72 kPa and the engine coolant and intake air temperature must exceed -7°C.

- Engine running. Main relay voltage exceeding 10V. Output is active.


Fault criteria:


- Voltage exceeding 2V for 1 s.


Dependents:


- None.


System reaction to a fault:


- Fuel adaptation and purging are blocked.


OK report:


- Enable criteria fulfilled. Fault criteria not fulfilled within 60 s.


Fault handling: (See “Fault diagnosis, general” for more information.)


- Type III.


Diagnostic help

Fault diagnosis concerns an electrical fault in the connecting leads or in the valve.

Functions in the diagnostic tool related to the fault:


Activate valve output.


See also the description of activating functions under ”Fault diagnosis, general” for more information.

Checking the wiring

Jiggle the wiring harness at several points and in different directions to detect intermittent breaks and short circuits. Observe the multimeter, diagnostic tool or test lamp during the check.