Test readings, control module connections
| Test readings, control module connections |
| Scope |
This section contains the readings and instructions for measuring voltage levels on the SID unit.
| Remember |
| • |
Note the test conditions and use common sense when assessing the test result.
|
|
| • |
First check that the control module has a power supply and is grounded.
|
|
| • |
Then check all sensor inputs and signals from other systems.
|
|
| • |
Finally check the control module outputs. Remember that the test readings do not indicate whether the actuator is working.
|
|
| • |
If any reading is not OK, consult the wiring diagram to trace the leads, connectors or components which should be checked more thoroughly.
|
|
| • |
The specified test readings refer to those obtained with a calibrated Fluke 88/97.
|
|
| • |
The test readings show the signal's pulse ratio and pulse width. A test instrument with pulse ratio and pulse width measurement must be used. The sign indicates a positive trigger pulse, TRIG+.
|
|
| Control module connections |