Blended-air temperature sensor, RH
| Blended-air temperature sensor, RH | 
| 1. | 
       Remove the glove box (A), see
       
        Glove box
       
       .
        | 
     |
| 2. | 
       Pull the sensor (A) from the air duct, which leads to the lower part of the panel, by releasing the clips.
        
       
        | 
     |
| 3. | 
       Remove the radio section (A) and the ACC control panel (B).
        
       
        | 
     |
| 4. | 
       Unplug the lower connector (A) (grey) from the heating and ventilation unit.
        
       
        | 
     |
| 5. | 
       Withdraw the pins in question from the connector (B).
        | 
     |
| 6. | 
       Pull out the sensor (C).
        | 
     |
| Note | ||
| 
        The leads in question are taped on to a wiring harness. Removal can be facilitated by cutting off the leads in question at a suitable place and by using new leads when refitting.  | 
     
| To fit | 
   
   | 1. | 
       Insert new cables (B).
        | 
     |
| 2. | 
       Refit the connector in the lower bracket for the heating and ventilation unit (A).
        | 
     |
| 3. | 
       Refit the sensor to the lower part of the panel (A).
        
       
        | 
     |
| 4. | 
       Fit the radio section (A) and the ACC control panel (B).
        
       
        | 
     |
| 5. | 
       Fit the glove box (A), see
       
        Glove box
       
       .
        
       
        | 
     |
| Note | ||
| 
        Wire with new leads during fitting. Fixate the new leads to the original wiring harness.  | 
     