Blended-air temperature sensor, RH
Blended-air temperature sensor, RH |
1. |
Remove the glove box (A), see
Glove box
.
|
2. |
Pull the sensor (A) from the air duct, which leads to the lower part of the panel, by releasing the clips.
|
3. |
Remove the radio section (A) and the ACC control panel (B).
|
4. |
Unplug the lower connector (A) (grey) from the heating and ventilation unit.
|
5. |
Withdraw the pins in question from the connector (B).
|
6. |
Pull out the sensor (C).
|
Note | ||
The leads in question are taped on to a wiring harness. Removal can be facilitated by cutting off the leads in question at a suitable place and by using new leads when refitting. |
To fit |
1. |
Insert new cables (B).
|
2. |
Refit the connector in the lower bracket for the heating and ventilation unit (A).
|
3. |
Refit the sensor to the lower part of the panel (A).
|
4. |
Fit the radio section (A) and the ACC control panel (B).
|
5. |
Fit the glove box (A), see
Glove box
.
|
Note | ||
Wire with new leads during fitting. Fixate the new leads to the original wiring harness. |