Recirculation Flap
| Recirculation Flap | 
| 1. | 
       Remove the glove box. See
       
        Glove box
       
       .
        Remove the trim from the side of the centre console.  | 
     |
| 2. | 
       Remove the recirculation flap screws. Pull the motor straight down.
        
       
        | 
     |
| 3. | 
       Unplug the connector.
        | 
     |
| 4. | 
       Cut the cable tie holding the wiring harness.
        | 
     |
| 5. | 
       Remove the connector from the plate.
        | 
     |
| Fitting | 
| 1. | 
       Lubricate the linkage arm with
       
        32 025 041 Silicone grease
       
       . Lift up the recirculation flap using a screwdriver. Put the recirculation motor in place and fit its bolts.
        
       
        | 
     |
| 2. | 
       Put back the connector in the plate.
        
       
        | 
     |
| 3. | 
       Fasten the wiring harness with a cable tie.
        | 
     |
| 4. | 
       Connect the contact.
        | 
     |
| 5. | 
       Replace the side trim on the centre console.
        
       
       Fit the glove box. See Glove box .  | 
     |