B1340
Read the instructions below then 
start the fault diagnostic procedure.
Symptom: Perceived temperature in cabin too high or too low compared to the set temperature.
 
  
 
 
  
  
   
   
    
    
     
     
     Solar Sensor. Open Circuit / Communication Fault
    
    
     
    
    
   
   
  
   Fault symptoms
  
  
   Perceived temperature in cabin too high or too low compared to the set temperature.
   
   
   
    Conditions
   
  
  
   The following conditions apply:
   
   
  
  
  
   
    
     
      | 
       •
       | 
      
       Open circuit or communication error.
        
        
       | 
     
    
   
  
  
   
    
     
      | 
       •
       | 
      
       The solar sensor sends an identification pulse continuously, 5V-0V-5V. The control module searches for identification pulses during time periods of 440 ms. When five successive measurements have been made with no pulse pattern, a DTC is generated.
        
        
       | 
     
    
   
  
  
   
    
     
      | 
       •
       | 
      
       The diagnostic trouble code is deleted after the ignition has been switched on 20 times if the malfunction conditions have not been fulfilled.
        
        
       | 
     
    
   
  
  
   
    
     
      | 
       •
       | 
      
       When the diagnostic trouble code has been generated, the control module uses a default value, that being the latest valid value. When ignition is turned on, 0 W/m
       
        2
       
       .
        
        
       | 
     
    
   
  
  
  
   Diagnostic help
  
  
   Check that a value is obtained from all 5 directions.