B2380
Read the instructions below then 
start the fault diagnostic procedure.
Symptom: Experienced cabin temperature is too low when compared to the set temperature.
 
  
 
 
  
  
   
   
    
    
     
     
     Circulation Pump. Short to B+
    
    
     
     
     Circulation Pump. Open Circuit / Short to Ground
    
    
     
    
    
   
   
  
   Fault symptoms
  
  
   Experienced cabin temperature is too low when compared to the set temperature.
   
   
   
    Conditions
   
  
  
   The following conditions apply:
   
   
  
  
  
   
    
     
      | 
       •
       | 
      
       A short to B+ is indicated when the output for the circulation pump is activated and the voltage on pin 23 exceeds 6 V.
        
        
       | 
     
    
   
  
  
   
    
     
      | 
       •
       | 
      
       A short to ground is indicated when the output for the circulation pump is not activated and the voltage on pin 23 exceeds 6 V.
        
        
       | 
     
    
   
  
  
   
    
     
      | 
       •
       | 
      
       Measured every 440 ms and 5 consecutive measurements are required to set a diagnostic trouble code.
        
        
       | 
     
    
   
  
  
   
    
     
      | 
       •
       | 
      
       The diagnostic trouble code is cleared after the ignition has been turned on 20 times and the malfunction conditions have not been fulfilled.
        
        
       | 
     
    
   
  
  
   
    
     
      | 
       •
       | 
      
       When the diagnostic trouble code has been set the output is switched off.
        
        
       |