B2496
Read the instructions below then 
start the fault diagnostic procedure.
Symptom: Perceived temperature in cabin too high or too low compared to the set temperature.
 
  
 
 
  
  
   
   
    
    
     
     
     Heater Flap Motor Left. Flap Jammed. Note: May set if not calibrated.
    
   
   
    
    
    
     
    
    
   
   
  
   
  
  
  
   Fault symptoms
  
  
   Perceived temperature in cabin too high or too low compared to the set temperature.
   
   
   
    Conditions
   
  
  
   The following conditions apply:
   
   
  
  
  
   
    
     
      | 
       •
       | 
      
       When the stepping motor operates in the range 10-90 % of its total range (which is 0-100 %), the control module senses if the power consumption is above a certain value, and if this is the case, sets the diagnostic trouble code for jammed flap.
        
        
       | 
     
    
   
  
  
   
    
     
      | 
       •
       | 
      
       The diagnostic trouble code can be set if the control module has not been calibrated.
        
        
       | 
     
    
   
  
  
   
    
     
      | 
       •
       | 
      
       Continuous monitoring and when calibrating.
        
        
       |