Parking heater
| Parking heater | 
  
  The parking heater applies B+ on ACC unit pin 3 when the coolant temperature by the parking heater outlet reaches 40°C. When the ignition is off, the following results:
| • | 
       Air-mixing flaps controlled automatically according to the set temperature.
        | 
     |
| • | 
       Air distribution flap in defrost position for 25 min and then in defrost/floor position.
        | 
     |
| • | 
       Recirculation flap in the recirculation position when the temperature is below -10°C, otherwise fresh air
        | 
     |
| • | 
       fan current 6 A
        | 
     |
| • | 
       display shows only fan speed
        | 
     |
| • | 
       Manual selections can be made with all the buttons except OFF, ECON and rear window heating. If AUTO is pressed, the full display is shown.
        | 
     |
The control module returns to normal as soon as B+ on pin 3 is interrupted or the ignition is turned to ON.
| Adjustment | 
The ACC unit can be adjusted with the diagnostics tool to:
| • | 
       put the air-mixing flap continuously in full heating position and the air distribution flap continuously in defrost position
        | 
     |
| • | 
       select another fan current
        | 
     |
| • | 
       select how long the air distribution flap stays in defrost position before defrost/floor is selected
        | 
     |