The parking heater applies B+ on ACC unit pin 3 when the coolant temperature by the parking heater outlet reaches 40°C. When the ignition is off, the following results:
• |
Air-mixing flaps controlled automatically according to the set temperature.
|
• |
Air distribution flap in defrost position for 25 min and then in defrost/floor position.
|
• |
Recirculation flap in the recirculation position when the temperature is below -10°C, otherwise fresh air
|
• |
fan current 6 A
|
• |
display shows only fan speed
|
• |
Manual selections can be made with all the buttons except OFF, ECON and rear window heating. If AUTO is pressed, the full display is shown.
|
The control module returns to normal as soon as B+ on pin 3 is interrupted or the ignition is turned to ON.
Adjustment |
The ACC unit can be adjusted with the diagnostics tool to:
• |
put the air-mixing flap continuously in full heating position and the air distribution flap continuously in defrost position
|
• |
select another fan current
|
• |
select how long the air distribution flap stays in defrost position before defrost/floor is selected
|