010
Symptom: Parking heater fails to start.
010 |

Fault symptom
Parking heater fails to start.Condition
Parking heater activated.B+ greater than 16 V.
Diagnostic help
Parking heater can be activated with Tech 2.Parking heater function can be programmed in SID.
Eberspächer diagnostics instrument used for diagnosis.
Diagnostic procedure

1 Check the battery
• |
Check that no battery charger is connected to the battery.
|
• |
Start the engine.
|
• |
Check battery voltage at different engine rpm.
|
• |
Red test lead: B+.
|
• |
Black test lead: B-.
|
• |
The reading obtained should be below 15.5 V.
|
Test results OK?
YES |
-
Go to point 3.
NO |
-
Go to point 2.
2 Check the component

• |
Check the accumulator and the regulator. See group 3 Electrical system, ’Components’.
|
Test results OK?
YES |
-
Go to point 3.
NO |
-
Repair or replace the faulty component.
-
Go to point 3.
3. Final check

• |
Delete DTCs in all systems.
|
• |
Contact: SID.
|
• |
Activate parking heater (ON).
|
• |
Perform a functionality check.
|
• |
Evaluate the functionality check.
|
• |
Check that the diagnostic trouble code has not recurred.
|
Test results OK?
YES |
-
Fault rectified successfully.
NO |
-
See ’Procedure for replacement of control module’.