P0444
Read the instructions below then 
start the fault diagnostic procedure.
Symptom: CHECK ENGINE.
 Possible smell of petrol or misfiring.
 
  
 
 
  
  
   
   
    
    
     
     
     EVAP Purge Valve Circuit. Open / Short to Ground
    
    
     
    
    
   
   
  
   Fault symptoms
  
  
  
   
  
  
   
    
     
      | 
       •
       | 
      
       Possible smell of petrol or misfiring.
        
        
       | 
     
    
   
  
  
  
   On-Board Diagnostics
  
  
   
    Type of diagnosis:
   
   
   
  
  
  
   
    
     
      | 
       -
       | 
      
       Continuous. But interrupted when fault criteria fulfilled and will not restart until next driving cycle.
        
        
       | 
     
    
   
  
  
  
   
    Enable criteria:
   
   
   
  
  
  
   
    
     
      | 
       -
       | 
      
       Engine running. Main relay voltage 10 V-16 V. Output not active.
        
        
       | 
     
    
   
  
  
  
   
    Fault criteria:
   
   
   
  
  
  
   
    
     
      | 
       -
       | 
      
       Voltage on output is below 2 V when the valve should have closed and the PWM signal should be high (purge valve normally open). Condition fulfilled within 10 periods that must occur within 60 sec. (It normally takes approx. 1 sec. to generate a DTC.)
        
        
       | 
     
    
   
  
  
  
   
    Dependents:
   
   
   
  
  
  
   
  
  
  
   
    System reaction to a fault:
   
   
   
  
  
  
   
  
  
  
   
    OK report:
   
   
   
  
  
  
   
    
     
      | 
       -
       | 
      
       Enable criteria fulfilled. Fault criteria not fulfilled within 60 s.
        
        
       | 
     
    
   
  
  
  
   
    Fault handling:
   
   (See section
   
    Fault handling III, other emission-related components and functions
   
   for more information.)
   
   
  
  
  
   
  
  
  
   Diagnostic help
  
  
   Fault diagnosis concerns an electrical fault in the connecting leads or in the valve.
   
   
  
  
   Functions in the diagnostic tool related to the fault:
   
   
  
  
  
   
  
  
  
   See also description of activating functons under
   
    Menu "Activating Functions"
   
   for more information.
   
   
   
    Checking the wiring
   
  
  
   Jiggle the wiring harness at several points and in different directions to detect intermittent breaks and short circuits. Observe the multimeter, diagnostic tool or test lamp during the check.