P1132
Read the instructions below then 
start the fault diagnostic procedure.
Symptom: CHECK ENGINE.
 
  
 
 
  
  
   
   
    
    
     
     
     O2S. Switch point - rich. Sensor 1
    
    
     
    
    
   
   
  
   Fault symptoms
  
  
  
   
  
  
  
   On-Board Diagnostics
  
  
   
    Type of diagnosis:
   
   
   
  
  
  
   
    
     
      | 
       -
       | 
      
       Continuous. Terminated when fault criteria fulfilled. Restarts next driving cycle.
        
        
       | 
     
    
   
  
  
  
   
    Enable criteria:
   
   
   
  
  
  
   
    
     
      | 
       -
       | 
      
       General conditions for this trouble code: Atmospheric pressure must exceed 72 kPa and the engine coolant and intake air temperature must exceed -7°C.
        
        
       | 
     
    
   
  
  
   
    
     
      | 
       -
       | 
      
       Engine running. Closed loop blocked in rich or lean mode for a number of combustions in order to maintain a voltage of 0.6V from oxygen sensor 2. The number of combustions that is required is adapted.
        
        
       | 
     
    
   
  
  
  
   
    Fault criteria:
   
   
   
  
  
  
   
    
     
      | 
       -
       | 
      
       Closed loop blocked in lean mode for more than 35 combustions.
        
        
       | 
     
    
   
  
  
  
   
    Dependents:
   
   
   
  
  
  
   
    
     
      | 
       -
       | 
      
       P0115, P0116, P0117, P0118, P0119, P0131, P0132 and P0134.
        
        
       | 
     
    
   
  
  
  
   
    System reaction to a fault:
   
   
   
  
  
  
   
  
  
  
   
    OK report:
   
   
   
  
  
  
   
    
     
      | 
       -
       | 
      
       Number of adapted combustions has dropped at some time during the driving cycle.
        
        
       | 
     
    
   
  
  
  
   
    Fault handling:
   
   (See section
   
    Fault handling III, other emission-related components and functions
   
   for more information.)
   
   
  
  
  
   
  
  
  
   Diagnostic help
  
  
   Fault diagnosis concerns an internal fault in the sensor.
   
   
  
  
   Functions in the diagnostic tool related to the fault:
   
   
  
  
  
   
    
     
      | 
       •
       | 
      
       Diagnostic status for the diagnosis.
        
        
       | 
     
    
   
  
  
  
   
    
     
      | 
       Note
       | 
     
     
      | 
        
        Oxygen sensor receives reference oxygen from the surrounding air via the connecting cables. For this reason, electrical contact spray or grease
        
         must not
        
        be used on the oxygen sensor connector.
        
       |