P1133
Read the instructions below then 
start the fault diagnostic procedure.
Symptom: CHECK ENGINE.
Misfiring can occur before trouble code is generated.
 
  
 
 
  
  
   
   
    
    
     
     
     O2S Circuit. Low Voltage. Sensor 1.
    
    
     
    
    
   
   
  
   Fault symptoms
  
  
  
   
  
  
   
    
     
      | 
       •
       | 
      
       Misfiring can occur before trouble code is generated.
        
        
       | 
     
    
   
  
  
  
   On-Board Diagnostics
  
  
   
    Type of diagnosis:
   
   
   
  
  
  
   
    
     
      | 
       -
       | 
      
       Continuous. Terminated when fault criteria fulfilled. Restarts next driving cycle.
        
        
       | 
     
    
   
  
  
  
   
    Enable criteria:
   
   
   
  
  
  
   
    
     
      | 
       -
       | 
      
       Engine running. Closed loop active longer than 4s. Preheating current sensor 1 more than 300 mA. O2S2 has higher voltage than 0.7V for longer than 30s.
        
        
       | 
     
    
   
  
  
  
   
    Fault criteria:
   
   
   
  
  
  
   
    
     
      | 
       -
       | 
      
       O2S1 voltage is between 0.05 and 0.3V for longer than 30s.
        
        
       | 
     
    
   
  
  
  
   
    Dependents:
   
   
   
  
  
  
   
  
  
  
   
    System reaction to a fault
   
   :
   
   
  
  
  
   
    
     
      | 
       -
       | 
      
       Closed loop is blocked.
        
        
       | 
     
    
   
  
  
  
   
    OK report:
   
   
   
  
  
  
   
    
     
      | 
       -
       | 
      
       Enable criteria fulfilled and 60s has expired without a fault report.
        
        
       | 
     
    
   
  
  
  
   
    Fault handling:
   
   (See section
   
    Fault handling III, other emission-related components and functions
   
   for more information.)
   
   
  
  
  
   
  
  
  
   Diagnostic help
  
  
   Fault diagnosis concerns an electrical fault in connecting leads or in the sensor.
   
   
  
  
   Functions in the diagnostic tool related to the fault:
   
   
  
  
  
   
    
     
      | 
       •
       | 
      
       Diagnostic status for the diagnosis.
        
        
       | 
     
    
   
  
  
   
    
     
      | 
       •
       | 
      
       Oxygen Sensor Value, unit V.
        
        
       | 
     
    
   
  
  
  
   See also the description of readings under
   
    Menu "Read Values"
   
   for more information.
   
   
  
  
   
    
     
      | 
       Note
       | 
     
     
      | 
        
        Oxygen sensor receives reference oxygen from the surrounding air via the connecting cables. For this reason, electrical contact spray or grease
        
         must not
        
        be used on the oxygen sensor connector.
        
       | 
     
    
   
   
   
    Checking the wiring
   
  
  
   Jiggle the wiring harness at several points and in different directions to detect intermittent breaks and short circuits. Observe the multimeter, diagnostic tool or test lamp during the check.