Symptom: CHECK ENGINE.
 
  
 
 
  
  
   
   
    
    
     
     
     Combustion Detection Cyl. 3+4. Open Circuit / Short to B+.
    
    
     
    
    
   
   
  
   Fault symptoms
  
  
  
   
  
  
  
   On-Board Diagnostics
  
  
   
    Type of diagnosis:
   
   
   
  
  
  
   
    
     
      | 
       -
       | 
      
       Continuous. But interrupted when fault criteria fulfilled and will not restart until next driving cycle.
        
        
       | 
     
    
   
  
  
  
   
    Enable criteria:
   
   
   
  
  
  
   
    
     
      | 
       -
       | 
      
       General conditions for this trouble code: Atmospheric pressure must exceed 72 kPa and the engine coolant and intake air temperatures must exceed -7°C.
        
        
       | 
     
    
   
  
  
   
    
     
      | 
       -
       | 
      
       Engine running. Main relay voltage exceeding 10V. Ignition synchronized.
        
        
       | 
     
    
   
  
  
  
   
    Fault criteria:
   
   
   
  
  
  
   
    
     
      | 
       -
       | 
      
       Voltage exceeding 5V continuously during 200 combustions.
        
        
       | 
     
    
   
  
  
  
   
    Dependents:
   
   
   
  
  
  
   
  
  
  
   
    System reaction to a fault:
   
   
   
  
  
  
   
  
  
  
   
    OK report:
   
   
   
  
  
  
   
    
     
      | 
       -
       | 
      
       Enable criteria fulfilled. Fault criteria for P1312 or P1334 not fulfilled within 300 combustions.
        
        
       | 
     
    
   
  
  
  
   
    Fault handling:
   
   (See section
   
    Fault handling III, other emission-related components and functions
   
   for more information.)
   
   
  
  
  
   
  
  
  
   Diagnostic help
  
  
   Fault diagnosis concerns an electrical fault in the connecting leads.
   
   
  
  
  
   
    
     
      | 
       •
       | 
      
       Combustion Detection Cyl 3+4/Bank2, unit %
        
        
       | 
     
    
   
  
  
  
   Checking the wiring
  
  
   Jiggle the wiring harness at several points and in different directions to detect intermittent breaks and short circuits. Observe the multimeter, diagnostic tool or test lamp during the check.