P1659
Read the instructions below then start the fault diagnostic procedure.
Symptom: CHECK ENGINE.
| P1659 | 
Fault symptoms
| • | 
       CHECK ENGINE.
        | 
     |
On-Board Diagnostics
Type of diagnosis:| - | 
       Continuous. But interrupted when fault criteria fulfilled and will not restart until next driving cycle.
        | 
     |
Enable criteria:
| - | 
       Engine running. Main relay voltage exceeding 10V. Output is active.
        | 
     |
Fault criteria:
| - | 
       Output voltage exceeding 2V for more than 1 s.
        | 
     |
Dependents:
| - | 
       None.
        | 
     |
System reaction to a fault:
| - | 
       None.
        | 
     |
OK report:
| - | 
       As for P1110: Enable criteria fulfilled and amplitude below 1 kPa. Criteria must be fulfilled on three consecutive occasions during the same driving cycle.
        | 
     |
Fault handling: (See section Fault handling III, other emission-related components and functions for more information.)
| - | 
       Type III.
        | 
     |
Diagnostic help
Fault diagnosis concerns an electrical fault in the connecting leads or in the valve.Functions in the diagnostic tool related to the fault:
| • | 
       Activate valve output.
        | 
     |
See also the description of activations under Menu "Activation" for more information.