P1676
Read the instructions below then start the fault diagnostic procedure.
Symptom: Engine misfires or will not start.
| P1676 | 
Fault symptoms
| • | 
       Engine misfires or will not start.
        | 
     |
On-Board Diagnostics
Type of diagnosis:| - | 
       Continuous. But interrupted when fault criteria fulfilled and will not restart until next driving cycle.
        | 
     |
Enable criteria:
| - | 
       Crankshaft rotating. Main relay voltage above 6V.
        | 
     |
Fault criteria:
| - | 
       Voltage on one of the outputs below 2V if the output is not active or exceeding 2V if the output is active. Fault criteria fulfilled after 2 s.
        | 
     |
Dependents:
| - | 
       None.
        | 
     |
System reaction to a fault:
| - | 
       Closed loop is blocked.
        | 
     |
OK report:
| - | 
       Enable criteria fulfilled and fault criteria not fulfilled within 60 s.
        | 
     |
Fault handling: (See section Fault handling III, other emission-related components and functions for more information.)
| - | 
       Type III. CHECK ENGINE does not go on.
        | 
     |
Diagnostic help
Fault diagnosis concerns an electrical fault in connecting leads or in any of the injectors.Functions in the diagnostic tool related to the fault:
| • | 
       Activate outputs for all injectors.
        | 
     |
See also the description of activations under Menu "Activation" for more information.