SAAB WIS ONLINE

TWICE control module

TWICE control module


Program the TWICE control module function “Transit mode” to “No” as follows:


Connect the Tech 2 diagnostic tool to the data link connector under the steering wheel.

Turn the ignition ON and contact the TWICE control module.

Select menu Programming .

Select function Transit mode .

Select No .

Delete any diagnostic trouble codes in the TWICE control module.

Discontinue communication with the TWICE control module.

Turn the ignition switch to the OFF position.