To remove



1. Remove the glove box (A), see Glove box .

2. Pull the sensor (A) from the air duct, which leads to the lower part of the panel, by releasing the clips.


3. Remove the radio section (A) and the ACC control panel (B).


4. Unplug the lower connector (A) (grey) from the heating and ventilation unit.


5. Withdraw the pins in question from the connector (B).

6. Pull out the sensor (C).


Note

The leads in question are taped on to a wiring harness. Removal can be facilitated by cutting off the leads in question at a suitable place and by using new leads when refitting.


To fit



1. Insert new cables (B).

2. Refit the connector in the lower bracket for the heating and ventilation unit (A).

3. Refit the sensor to the lower part of the panel (A).


4. Fit the radio section (A) and the ACC control panel (B).


5. Fit the glove box (A), see Glove box .



Note

Wire with new leads during fitting. Fixate the new leads to the original wiring harness.