B1345
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Perceived temperature in cabin too high or too low compared to the set temperature.
Mixed Air Sensor Left. Short to Ground
Mixed Air Sensor Left. Open Circuit / Short to B+
Fault symptoms
Perceived temperature in cabin too high or too low compared to the set temperature.
Conditions
The following conditions apply:
•
|
Open circuit or short to B+ on pin 19 >4.9 V.
|
•
|
Short to ground on pin 19<0.1 V.
|
•
|
Measured every 440 ms and 5 consecutive measurements are required to set a diagnostic trouble code.
|
•
|
The diagnostic trouble code is deleted after the ignition has been switched on 20 times if the malfunction conditions have not been fulfilled.
|
•
|
When the diagnostic trouble code is set, the control module uses the default value, which is the relative opening of the air-mixing flap in question multiplied by the coolant temperature.
|