B2290

Read the instructions below then start the fault diagnostic procedure.

Symptom: Experienced temperature is too low compared to the set temperature. The cabin temperature cannot be adjusted on the right side.

B2290


Heater Flap Motor Right. Open Circuit

Heater Flap Motor Right. Short Circuit





Fault symptoms

Experienced temperature is too low compared to the set temperature. The cabin temperature cannot be adjusted on the right side.

Conditions

The following conditions apply:


When the current on one of the control module stepping motor outputs exceeds a certain value, the diagnostic trouble code for short circuit will be set.

If any of the stepping motor outputs sense that the control current is less than 55 mA, a diagnostic trouble code for open circuit is generated.

Continuous monitoring and when calibrating.