P1382
Read the instructions below then start the fault diagnostic procedure.
Symptom: Starting difficulties when cold.
| P1382 | 
Fault symptoms
| • | Starting difficulties when cold. | |
On-Board Diagnostics
Type of diagnosis:| - | Once per driving cycle. | |
Enable criteria:
| - | Heating not active for more than 6s. | |
Fault criteria:
| - | When input (pin 19) is shorted to ground for more than 3s. | |
Dependents:
| - | None. | |
System reaction to a fault:
| - | None. | |
OK report:
| - | Fault criteria not fulfilled. | |
Fault handling: (See section Fault handling III, other emissions-related components and functions for more information)
| - | Type III. | |
Diagnostic help
Fault diagnosis concerns an electrical fault in connecting leads or in the sensor.Functions in the diagnostic tool related to the fault:
| - | Read value:
       
       
       Glow Request | |
| - | Activate:
       
       
       Glow Request | |
See the description of read values under "Read Values" menu for more information.
See the description of activations under "Activate" menu for more information.

 
     
		