Checking the charge air bypass valve, 4-cyl.
| Checking the charge air bypass valve, 4-cyl. |
| 1. |
Disconnect the vacuum hose from the charge air bypass valve.
|
|
| 2. |
Connect the pressure/vacuum pump,
30 14 883 Pressure/vacuum pump
, and build negative pressure in the valve.
|
|
| 3. |
Check that the diaphragm is intact. If the diaphragm is damaged, no vacuum can be created.
|
|
| 4. |
Repeat points 2 and 3 but pump up a pressure.
|
|
| 5. |
Disconnect the pump.
|
|
| 6. |
Connect the vacuum hose.
|
|