SAAB WIS ONLINE

"Activate" menu

"Activate" menu



Important

Activate functions should always be used with discretion. Always deactivate an activated function before you go any further in the Tech 2 menu. Always delete any diagnostic trouble codes in the ESP unit or any other system once work is complete.




Note

When a system function is activated with the diagnostics tool, the control module executes a command which is not normal from a functional point of view. In activation mode the diagnostics tool checks the control module and the activation command should therefore be used with discrimination. An activated function will always be reset when you exit the activation mode and select a different diagnostics tool menu.


Activate Description Value
ABS Lamp

Turns the ABS warning lamp on and off.

ON/OFF

TCS Lamp

Turns the TCS indicator lamp on and off.

ON/OFF

TCS OFF Lamp

Turns the TCS OFF lamp on and off.

ON/OFF

Pump Motor

Turns the pump motor on and off.

ON/OFF

Engine Torque Reduction

The TC/ABS control modules requests Trionic for maximum engine torque limitation.



Front Left Inlet Valve

The valve is activated for 30 seconds with a frequency of 1 Hz.

ON/OFF

Front Left Outlet Valve

The valve is activated for 30 seconds with a frequency of 1 Hz.

ON/OFF

Front Right Inlet Valve

The valve is activated for 30 seconds with a frequency of 1 Hz.

ON/OFF

Front Right Outlet Valve

The valve is activated for 30 seconds with a frequency of 1 Hz.

ON/OFF

Rear Left Inlet Valve

The valve is activated for 30 seconds with a frequency of 1 Hz.

ON/OFF

Rear Left Outlet Valve

The valve is activated for 30 seconds with a frequency of 1 Hz.

ON/OFF

Rear Right Inlet Valve

The valve is activated for 30 seconds with a frequency of 1 Hz.

ON/OFF

Rear Right Outlet Valve

The valve is activated for 30 seconds with a frequency of 1 Hz.

ON/OFF

Pressure Increase Valve Front Left

The valve is activated for 30 seconds with a frequency of 1 Hz.

ON/OFF

Pressure Increase Valve Front Right

The valve is activated for 30 seconds with a frequency of 1 Hz.

ON/OFF

Pressure Relief Valve, Front Left

The valve is activated for 30 seconds with a frequency of 1 Hz.

ON/OFF

Pressure Relief Valve Front Right

The valve is activated for 30 seconds with a frequency of 1 Hz.

ON/OFF

Valve Test - Front Left

See Valve test



Valve Test - Front Right

See Valve test



Valve Test - Rear Left

See Valve test



Valve Test - Rear Right

See Valve test