B2290
Read the instructions below then 
start the fault diagnostic procedure.
Symptom: Experienced temperature is too low compared to the set temperature. The cabin temperature cannot be adjusted on the right side.
 
  
 
 
  
  
   
   
    
    
     
     
     Heater Flap Motor Right. Open Circuit
    
    
     
     
     Heater Flap Motor Right. Short Circuit
    
   
   
    
    
    
      
    
    
   
   
  
    
  
  
  
   Fault symptoms
  
  
   Experienced temperature is too low compared to the set temperature. The cabin temperature cannot be adjusted on the right side.
   
   
   
    Conditions
   
  
  
   The following conditions apply:
   
   
  
  
  
   
    
     
      | • | When the current on one of the control module stepping motor outputs exceeds a certain value, the diagnostic trouble code for short circuit will be set. 
 
 | 
    
   
  
  
   
    
     
      | • | If any of the stepping motor outputs sense that the control current is less than 55 mA, a diagnostic trouble code for open circuit is generated. 
 
 | 
    
   
  
  
   
    
     
      | • | Continuous monitoring and when calibrating. 
 
 |