B2375
Read the instructions below then 
start the fault diagnostic procedure.
Symptom: Perceived temperature in cabin too high or too low compared to the set temperature.
 
  
 
 
  
  
   
   
    
    
     
     
     Heat Exchanger Solenoid. Short to B+
    
    
     
     
     Heat Exchanger Solenoid. Open Circuit / Short to Ground
    
    
      
    
    
   
   
  
   Fault symptoms
  
  
   Perceived temperature in cabin too high or too low compared to the set temperature.
   
   
   
    Conditions
   
  
  
   The following conditions apply:
   
   
  
  
  
   
    
     
      | • | A short to B+ is indicated when the output for the heat exchanger solenoid is activated and the voltage on pin 24 exceeds 6 V. 
 
 | 
    
   
  
  
   
    
     
      | • | A short to ground is indicated when the output for the circulation pump is not activated and the voltage on pin 24 exceeds 6 V. 
 
 | 
    
   
  
  
   
    
     
      | • | Measured every 440 ms and 5 consecutive measurements are required to set a diagnostic trouble code. 
 
 | 
    
   
  
  
   
    
     
      | • | The diagnostic trouble code is cleared after the ignition has been turned on 20 times and the malfunction conditions have not been fulfilled. 
 
 | 
    
   
  
  
   
    
     
      | • | When the diagnostic trouble code has been set the output is switched off. 
 
 |