Combustion chamber
| Combustion chamber | 
| To remove | 
| 1. | Remove the cover over the combustion air fan.   
 | |||||||
| 2. | Remove the four control module bolts. | |
| 3. | Carefully extract the control module, unplug the connector and remove the control module from the heater.   | |
| 4. | Remove the centre housing.   | |
| 5. | Remove the combustion air fan. Remove the gasket.   | |
| 6. | Lift out the combustion chamber. Remove the gasket.   | |
| To fit | 
 
    
    | 1. | Make sure that the heat exchanger's O-ring is undamaged and that no leakage has occurred. Change as necessary. | |
| 2. | Clean the contact surfaces. Change the gasket and fit the combustion chamber. It can be fitted in only one way. | |
| 3. | Change the gasket and fit the combustion air fan. Align the gasket with the three holes.   | |
| 4. | Fit the centre housing.   | |
| 5. | Plug connector B2 into the control module.   | |
| 6. | Fit the control module.   | |
| 7. | Fit the cover. 
 | |||||||

 
		